Industry Info


Facts & Figures
 (Including Plant Capacities)


Technical Datasheets

Links
 

Industry Info

 
Property Test Method Unit Resin Grades
57-01 57-11 61-11 63-01 67-01 67-11 69-11 70-11 70-21 74-11
k-value BFG
893-B
(1% in Cyclohexanon at 30°C)
- 57±1 57±1 61±1 63±1 67±1 67±1 69±1 70±1 70±1 74±1
Heat Loss BFG 362-H % max 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3
Particle size
- Retained on 40 mesh

- Retained on 60 mesh

- Retained through 140 mesh
BFG 812-H % max  

Traces

5

50

 

Traces

5

50

 

Traces

5

50

 

Traces

10

25

 

Traces

10

25

 

Traces

10

25

 

Traces

10

25

 

Traces

10

25

 

Traces

10

25

 

Traces

10

25

Porosity (DOP Absoprtion) BFG 1094-A ml/g 0.17-0.27 0.17-0.27 0.17-0.27 0.16-0.26 0.19-0.25 0.26-0.32 0.21-0.31 0.27-0.37 0.27-0.37 0.25-0.34
Bulk Density BFG 690-Fab g/ml 0.54±0.03 0.54±0.03 0.54±0.03 0.57±0.03 0.56±0.03 0.56±0.03 0.56±0.03 0.48±0.03 0.48±0.03 0.50±0.03
Residual VCM Content BFG 1005-F ppm max. 2 2 2 1 1 1 1 1 1 1
Dark Resin Count BFG 1064 No. max. 12 4 4 4 4 4 4 4 4 10
Fish Eye Count BFG 909-G No. max. 20 10 10 20 20 10 10 10 10 10
Flow Time BFG 692-E Sec. max 25 25 25 25 25 25 25 25 25 25
Electrical Conducitivity ASTM D-1755
(method 14)
Microm
hos / cm/g
- - - - <6 <6 - >6 >6 -
 
  Nomenclature Key: 
- The first two digits of the grade code indicate typical k-value
- The third digit indicates the following
   0 - General Purpose Applications
   1 - Low "Fish-Eye" Count
   2 - Suitable for Electrical Application
- The fourth digit is a manufacturing code